What are the common faults of metering pumps? - Metering pump manufacturers tell you
Edit:Lianyungang Mi Lu Luo Pump Industry Co., Ltd   UpDate:2016-06-17

What are the common faults of metering pumps? - Metering pump manufacturers tell you

1) metering pump suction is not normal

Rotate to 100% of the stroke length. This allows the entire set of components to rotate to the backsheet drain drain holes aligned with the bottom of the pump. Adjust the hydraulic end and diaphragm to the proper position during pump operation.

The duration of the pulse may not be long enough for the reaction time. With respect to the standard pulse width of 80msec, the flow monitor pulse width extension can be activated to increase the pulse width to 300msec. Activate the smart switch, remove the cover of the fixed circuit board, remove the jumper X-1. This activates the extended function, allowing more time before the fault indication.

Dosing pump installed from the exhaust pump head, using self-irrigation liquid. Keep the aspiration line as short as possible.

2) Replace the metering pump diaphragm

In the removal of the old diaphragm, often encountered trouble. On how to remove the old diaphragm to provide some additional advice.

⒈ After the pump head is loose, remove the pump head before adjusting the stroke length to 10%. Can ensure that the electromagnetic axis has enough pressure to maintain its connection is stable, so you can unscrew the diaphragm.

⒉ pull out the hydraulic end of the screw from the socket out. Grasp the liquid side to rotate counterclockwise. A little resistance, you can spin off the diaphragm.

⒊ measurement of chemicals may be in the hydraulic end of the crystallization, resulting in one-way valve ball and valve seat can not work properly.

⒋ There may be gas leakage at the suction end of the metering pump. The hydraulic end suction side connector may be missing the O-ring or the suction valve connection is loose.

3) with a flow monitor measurement of a high viscosity medium, in the process of receiving fluid flow signal indicating the failure, how can we solve this problem?

Remove the hydraulic head by loosening the four pump head screws. Rotate the stroke length to 10% and grab the hydraulic end and slide it out of the screw hole, so the screws do not touch them, but also hold the backplane and the diaphragm. And then counterclockwise rotation of this part, a little resistance, the diaphragm will be loose from the electromagnetic axis down. If the diaphragm is not loosened, use some oil on the contact surface of the diaphragm and the electromagnetic shaft. Place a few minutes later, with a plastic hammer gently tapping the diaphragm. And then proceed again as described above.

4) How to prevent the metering pump stroke positioning motor burned?

⒈ remove the fixed pump head of the four screws. The screw position is on the back of the metering pump.

⒉ see if the exhaust pipe is installed and the drain valve is closed? The drain valve needs to be opened during metering pump priming. Note: Not all metering pumps have drain valves.

3. Install the pump head after the diaphragm is installed and the backplane drain drain hole is placed in the vertical position. Make sure that the suction valve is aligned with the drain drain hole and that the screw at the hydraulic end aligns with the corresponding four holes.

5) hydraulic metering pump flow becomes smaller or inaccurate?

⒈ unscrew the valve in the three valves.

⒉ full charge through the fill valve.